dc.contributor.advisor | Hložek, Tomáš | |
dc.creator | Pavelková, Lucia | |
dc.date.accessioned | 2025-06-19T19:37:27Z | |
dc.date.available | 2025-06-19T19:37:27Z | |
dc.date.issued | 2025 | |
dc.identifier.uri | http://hdl.handle.net/20.500.11956/198960 | |
dc.description.abstract | The thesis focuses on the quantitative analysis of selected representatives of synthetic cathinones (pentedrone, pentylone, butylone, 4-ethylmethcathinone, 3,4-methylenedioxy- alpha-pyrrolidinobutyrophenone) using modern chromatographic techniques. Special emphasis was placed on the use of high-performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS), which is one of the most reliable methods in toxicological practice. Chromatographic conditions, including the selection of columns and mobile phases (for HPLC-MS/MS), were optimized to ensure high sensitivity, accuracy, precision, repeatability, and reproducibility of results. Based on calibration curves and signal-to-noise ratios, quantification limits for individual synthetic cathinones were determined. For the HPLC-MS/MS method, these limits ranged from 0.1 to 0.6 ng/ml. Keywords: new synthetic drugs, synthetic cathinones, high-performance liquid chromatography with tandem mass spectrometric detection (HPLC-MS/MS) | en_US |
dc.description.abstract | V diplomovej práci sa pozornosť venovala kvantitatívnej analýze vybraných zástupcov syntetických katinónov (pentedron, pentylon, butylon, 4-etylmetkatinon, 3,4-metyléndioxy- alfa-pyrrolidinobutiofenon) za použitia moderných chromatografických techník. Mimoriadny dôraz sa kládol na použitie vysokoúčinnej kvapalinovej chromatografie s tandemovou hmotnostnou spektrometriou (HPLC-MS/MS), ktorá patrí medzi najspoľahlivejšie metódy v toxikologickej praxi. Chromatografické podmienky vrátane výberu kolón a mobilných fáz (pre HPLC-MS/MS), boli optimalizované tak, aby bola zabezpečená vysoká citlivosť, presnosť, správnosť, opakovateľnosť a medziľahlá presnosť výsledkov. Na základe kalibračných kriviek a pomerov signál/šum boli stanovené limity kvantifikácie pre jednotlivé syntetické katinóny. Pre metódu HPLC-MS/MS sa tieto limity pohybovali v rozmedzí od 0,1 do 0,6 ng/ml. Kľúčové slová: nové syntetické drogy, syntetické katinóny, vysokoúčinná kvapalinová chromatografia s tandemovou hmotnostnou detekciou (HPLC-MS/MS) | cs_CZ |
dc.language | Slovenčina | cs_CZ |
dc.language.iso | sk_SK | |
dc.publisher | Univerzita Karlova, Přírodovědecká fakulta | cs_CZ |
dc.subject | new synthetic drugs | en_US |
dc.subject | synthetic cathinones | en_US |
dc.subject | high-performance liquidchromatography with tandem mass spectrometric detection (HPLC-MS | en_US |
dc.subject | MS) | en_US |
dc.subject | nové syntetické drogy | cs_CZ |
dc.subject | syntetické katinóny | cs_CZ |
dc.subject | vysokoúčinná kvapalinováchromatografia s tandemovou hmotnostnou detekciou (HPLC-MS | cs_CZ |
dc.subject | MS) | cs_CZ |
dc.title | Vývoj chromatografických techník v spojení s hmotnostnou detekciou pre kvantitatívnu analýzu nových syntetických drog v biologických vzorkách | sk_SK |
dc.type | diplomová práce | cs_CZ |
dcterms.created | 2025 | |
dcterms.dateAccepted | 2025-05-27 | |
dc.description.department | Katedra analytické chemie | cs_CZ |
dc.description.department | Department of Analytical Chemistry | en_US |
dc.description.faculty | Přírodovědecká fakulta | cs_CZ |
dc.description.faculty | Faculty of Science | en_US |
dc.identifier.repId | 267248 | |
dc.title.translated | Development of chromatographic techniques with mass spectrometric detection for the quantitative analysis of new synthetic drugs in biological samples | en_US |
dc.title.translated | Vývoj chromatografických technik ve spojení s hmotnostní detekcí pro kvantitativní analýzu nových syntetických drog v biologických vzorcích | cs_CZ |
dc.contributor.referee | Sobotníková, Jana | |
thesis.degree.name | Mgr. | |
thesis.degree.level | navazující magisterské | cs_CZ |
thesis.degree.discipline | Clinical and Toxicological Analysis | en_US |
thesis.degree.discipline | Klinická a toxikologická analýza | cs_CZ |
thesis.degree.program | Clinical and Toxicological Analysis | en_US |
thesis.degree.program | Klinická a toxikologická analýza | cs_CZ |
uk.thesis.type | diplomová práce | cs_CZ |
uk.taxonomy.organization-cs | Přírodovědecká fakulta::Katedra analytické chemie | cs_CZ |
uk.taxonomy.organization-en | Faculty of Science::Department of Analytical Chemistry | en_US |
uk.faculty-name.cs | Přírodovědecká fakulta | cs_CZ |
uk.faculty-name.en | Faculty of Science | en_US |
uk.faculty-abbr.cs | PřF | cs_CZ |
uk.degree-discipline.cs | Klinická a toxikologická analýza | cs_CZ |
uk.degree-discipline.en | Clinical and Toxicological Analysis | en_US |
uk.degree-program.cs | Klinická a toxikologická analýza | cs_CZ |
uk.degree-program.en | Clinical and Toxicological Analysis | en_US |
thesis.grade.cs | Výborně | cs_CZ |
thesis.grade.en | Excellent | en_US |
uk.abstract.cs | V diplomovej práci sa pozornosť venovala kvantitatívnej analýze vybraných zástupcov syntetických katinónov (pentedron, pentylon, butylon, 4-etylmetkatinon, 3,4-metyléndioxy- alfa-pyrrolidinobutiofenon) za použitia moderných chromatografických techník. Mimoriadny dôraz sa kládol na použitie vysokoúčinnej kvapalinovej chromatografie s tandemovou hmotnostnou spektrometriou (HPLC-MS/MS), ktorá patrí medzi najspoľahlivejšie metódy v toxikologickej praxi. Chromatografické podmienky vrátane výberu kolón a mobilných fáz (pre HPLC-MS/MS), boli optimalizované tak, aby bola zabezpečená vysoká citlivosť, presnosť, správnosť, opakovateľnosť a medziľahlá presnosť výsledkov. Na základe kalibračných kriviek a pomerov signál/šum boli stanovené limity kvantifikácie pre jednotlivé syntetické katinóny. Pre metódu HPLC-MS/MS sa tieto limity pohybovali v rozmedzí od 0,1 do 0,6 ng/ml. Kľúčové slová: nové syntetické drogy, syntetické katinóny, vysokoúčinná kvapalinová chromatografia s tandemovou hmotnostnou detekciou (HPLC-MS/MS) | cs_CZ |
uk.abstract.en | The thesis focuses on the quantitative analysis of selected representatives of synthetic cathinones (pentedrone, pentylone, butylone, 4-ethylmethcathinone, 3,4-methylenedioxy- alpha-pyrrolidinobutyrophenone) using modern chromatographic techniques. Special emphasis was placed on the use of high-performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS), which is one of the most reliable methods in toxicological practice. Chromatographic conditions, including the selection of columns and mobile phases (for HPLC-MS/MS), were optimized to ensure high sensitivity, accuracy, precision, repeatability, and reproducibility of results. Based on calibration curves and signal-to-noise ratios, quantification limits for individual synthetic cathinones were determined. For the HPLC-MS/MS method, these limits ranged from 0.1 to 0.6 ng/ml. Keywords: new synthetic drugs, synthetic cathinones, high-performance liquid chromatography with tandem mass spectrometric detection (HPLC-MS/MS) | en_US |
uk.file-availability | V | |
uk.grantor | Univerzita Karlova, Přírodovědecká fakulta, Katedra analytické chemie | cs_CZ |
thesis.grade.code | 1 | |
uk.publication-place | Praha | cs_CZ |
uk.thesis.defenceStatus | O | |